This BMS is designed for battery packs for the inverter, electric
bicycles and the electric motorcycles It can be applied to
lithium batteries with different chemical properties, such as
lithium ion, Li-polymer. Lithium iron phosphate, etc. The
protection board has strong loading capacity and the maximum
continuous discharge current can reach 200A
● 3-30 cell series protection
● Various protection functions for charging and discharging
● Discharge over current, short circuit protection functional
processes of hardware
● reserves the discharging control switch and the position of
discharging temperature protection,
● Very low static current consumption
● Containing charging equalization function
Advantages:
1. Intelligent and powerful MOS, imported IC, integrated solution.
2. Equipped with temperature sensor, preserved control switch.
3. Factory sales, the more the quantity, the lower the price.
4. Support customization (the size of PCB / the material and length
of balance wires and output line / the replacement of Aluminum
shell material / change parameters / increase function of data
storage )
Protection function description
Overcharge protection:
When the battery is under the charging state, the voltage keeps
going up. When the protection board detects that the voltage of any
cell is higher than the overcharge protection value, the protection
board will start timing immediately.When the time reaches the
overcharge protection delay, the protection board will turn off the
charging MOS tube, at that time, it cannot be charged.
Overcharge protection recovery:
After the over voltage protection appears on the protection board,
the battery voltage will going
down under the static or discharge state of the battery. When the
protection board detects that each voltage is lower than the
recovery voltage of the overcharge protection, the protection board
will output a signal and turn on the charging MOS tube to charge.
Over-discharge protection:
When the battery is under the discharge state, the voltage keeps
going down. When the protection board detects that the voltage of
any cell is lower than the overcharge protection value, the
protection board will start timing immediately. When the time
reaches the over discharge protection delay, the output signal of
the protection board will turn off the discharge MOS tube, the load
lock circuit will work, but, it cannot discharge at this time.
Over discharge protection recovery:
After the over discharge protection appears on the protection
board, the battery voltage will
going up under the static or discharge state of the battery. When
the protection board detects that each voltage is higher than the
recovery voltage of the over discharge protection. At this time,
disconnect the load or charge, the protection board will output a
signal and turn on the charging MOS tube to charge.
Over current protection:
When the battery is under the static or discharge state, the
current suddenly increases. When the protection board detects that
the current reaches the overcurrent protection value, the
protection board will start timing at that time. When the current
duration in the circuit reaches the over current protection delay
time, the output signal of the protection board will turn off the
discharge MOS tube, and the load lock circuit will work. At this
time, the discharge cannot be conducted.
Over current protection recovery:
After the discharge over current protection appears on the
protection board, the discharge MOS tube is turned off, and the
current in the loop becomes 0. At this time, the load is
disconnected or charged, the output signal of the protection board
will turn on the discharge MOS tube to discharge.